Descripción
2
• Power Quality analysis
• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current/voltage value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software «KEW LOG Soft 2» is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery)
Normal Recording Mode
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)
Range | RMS Accuracy |
---|---|
100.0mA | ±2.0%rdg±0.9%f.s.+ Accuracy of Sensor |
Other ranges | ±1.5%rdg±0.7%f.s.+ Accuracy of Sensor |
Crest Factor | 2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s. |
*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren’t guaranteed.
Trigger Recording Mode (AC 50/60Hz sine wave)
Range | Accuracy |
---|---|
100.0mA | ±3.5%rdg±2.2%f.s.+ Accuracy of Sensor |
Other ranges | ±3.0%rdg±2.0%f.s.+ Accuracy of Sensor |
Capture Recording Mode
Range | Accuracy |
---|---|
100.0mA | ±3.0%rdg±1.7%f.s.+ Accuracy of Sensor |
Other ranges | ±2.5%rdg±1.5%f.s.+ Accuracy of Sensor |
Recording mode | Normal, Trigger, Capture, Power Quality Analysis |
---|---|
Operating system | Successive Approximation (CH1 single synchronized sampling) |
Rated max. working voltage | AC 9.9Vrms, 14V peak value |
Number of input channel | 3ch |
Measuring method | True RMS |
RMS measuring interval | approx. 100ms |
Sampling interval | Normal/Trigger mode : approx. 1.65ms/CH Capture mode : approx. 0.55ms (waveform: at every 1.1ms) P.Q.A. mode : approx. 0.55ms |
Low battery warning | Battery mark display (in 4 levels) |
Over-range indication | «OL» mark is displayed when exceeding the measuring range |
Auto power off | Power-off function operates automatically after a switch remains for 3min. (when recording is stopped) |
Possible measurement time | Approx. 10 days (with alkaline LR6 batteries) |
Applicable standards | IEC 61010-1:2001 CAT III 300V Pollution degree2 IEC 61326 (EMC standard) |
Dimensions | 111(L)×60(W)×42(D)mm |
Weight | Approx. 265g |
Included Accessories | Alkaline battery LR6×4pcs, 9118 (Carrying case) PC software «KEW LOG Soft 2», 7148 (USB cable) Instruction manual, Quick manual, Install manual, USB Notice sheet |
Optional Accessories | 8146/8147/8148 (Leakage & Load current Clamp Sensor), 8121/8122/8123 (Load current Clamp Sensor), 8129/8130 (Flexible Clamp Sensor), 8309 (Voltage Sensor: only KEW 5020), 8320 (AC Adapter), 9135 (Carrying bag), 9119 (Hard carry case), 7185 (Extension cable for sensor) |
Esta web utiliza cookies para que podamos ofrecerte la mejor experiencia de usuario posible.
La información de las cookies se almacena en tu navegador y realiza funciones tales como reconocerte cuando vuelves a nuestra web o ayudar a nuestro equipo a comprender qué secciones de la web encuentras más interesantes y útiles.
Pincha en cada enlace para obtener más información sobre: aviso legal, privacidad y cookies
Las cookies estrictamente necesarias tiene que activarse siempre para que podamos guardar tus preferencias de ajustes de cookies.
Básicamente la web no funcionará bien si no las activas.
Estas cookies son:
Si desactivas esta cookie no podremos guardar tus preferencias. Esto significa que cada vez que visites esta web tendrás que activar o desactivar las cookies de nuevo.
Esta web utiliza Google Analytics para recopilar información anónima tal como el número de visitantes del sitio, o las páginas más populares.
Dejar esta cookie activa nos permite mejorar nuestra web.
¡Por favor, activa primero las cookies estrictamente necesarias para que podamos guardar tus preferencias!
Más información sobre nuestra política de cookies